nitrogen removal of anammox cultures under different enrichment conditions. | anammox bacteria in sludge from an anoxic tank of a municipal wastewater treatment plant at nongkhaem, bangkok, thailand were enriched in two sequencing batch reactors (sbrs; sbr-1 and sbr-2), under different conditions. sbr-1 was open to the atmosphere, while sbr-2 was closed and flushed with a mixture of 95% argon and 5% co(2) during the fill period in order to provide strict anaerobic conditions. the specific nitrogen removal rates of sbr-1 and sbr-2 were 0.43 g n/g vss-d and 2.59 g n/g vss-d ... | 2010 | 20945242 |